Boiler model | K-100 | K-140 | K-190 | K-220 | K-250 | K-320 | K-400 | K-500 | K-600 | K-700 | K-950 | K-1250 |
Boiler type | Water-heating solid fuel boiler of manual loading of fuel, steel tubular heat exchanger |
Nominal heat output(QN), kW *1 | 100 | 140 | 190 | 220 | 250 | 320 | 400 | 500 | 600 | 700 | 950 | 1250 |
Minimum heat output (Qmin), kW *1 | 30 | 42 | 57 | 75 | 96 | 120 | 150 | 180 | 216 | 255 | 285 | 375 |
Heating area with thermal resistance not less than 2.5 m2 · K / W, m2 | 400…1200 | 500…1600 | 600…2200 | 700…2700 | 750…2900 | 1000…3700 | 1200…4500 | 1500…5500 | 1800…6500 | 2300…7700 | 3000…11000 | 3700…14000 |
Efficiency not less than, % *1 | 83 |
Service life is not less, in years | 10 |
Fuel used | firewood, wood chips, sawdust and peat briquettes, coal*2 |
Fuel consumption, kg / hour *1 | 36 | 50 | 68 | 79 | 90 | 115 | 143 | 179 | 215 | 251 | 341 | 448 |
Combustion chamber size | H - height, mm B - width, mm L - length, mm | 620 500 730 | 620 500 930 | 770 680 1000 | 770 680 1200 | 820 680 1400 | 970 880 1300 | 970 880 1500 | 1100 1000 1700 | 1100 1000 1900 | 1100 1000 2060 | 1035 1260 2140 | 1035 1260 2510 |
volume, dm3 (l) | 226 | 288 | 523 | 628 | 733 | 1100 | 1280 | 1700 | 2090 | 2266 | 2730 | 3240 |
Fuel loading port B x H, mm: | 400 x 450 | 400 x 450 | 600x620 | 600 x 620 | 600 x 620 | 600х620 | 600х620 | 600х620 | 600х620 | 600х620 | 700х720 | 700х720 |
Nominal chimney drauft, (Pa) *4 | 0,25 (25) |
Minimum chimney draft, mbar (Pa) | 1,8 (180) | 1,9 (190) | 2,0 (200) | 2,15 (215) | 2,3 (230) | 2,4 (240) | 2,7 (270) | 2,9(290) | 3,1 (310) | 3,3(330) | 3,4(340) | 3,6(360) |
recommended to install together with a multicyclone *3 | MC-2 | MC-2 | MC-2 | MC-3 | MC-3 | MC-4 | MC-6 | MC-6 | MC-8 | MC-8 | MC-10 | MC-10 |
Aerodynamic drag, at QN, not more than, Pa | 45 | 55 | 105 | 115 | 125 | 210 | 220 | 260 | 290 | 300 | 310 | 330 |
The temperature of the exhaust gases not more than | 230 |
Volume of gases leaving the boiler, m3 / h *1 | 484 | 678 | 920 | 1065 | 1211 | 1550 | 1936 | 2421 | 2906 | 3390 | 4601 | 6054 |
Dimensions of chimneys, mm | 240х240 | 240х240 | 290х290 | 290х290 | 290х290 | Ø 325 | Ø 325 | Ø 325 | Ø 380 | Ø 480 | Ø 480 | Ø 480 |
Maximum working water pressure, bar (MPa) | 6,0 (0,6) |
Minimum allowable water pressure, bar (MPa) | 1,5 (0,15) |
Boiler operating temperature range, ºC | 60-110 |
Дебет води при Δt =20 ºC, т/год Water flow at Δt = 20 ºC, t /h | 4,26 | 5,97 | 8,11 | 9,39 | 10,68 | 13,67 | 17,09 | 21,37 | 25,65 | 29,93 | 40,62 | 53,5 |
Hydraulic resistance atΔt =20 ºC, м H2O | 0,36 | 0,37 | 0,38 | 0,39 | 0,40 | 0,42 | 0,43 | 0,43 | 0,44 | 0,45 | 0,48 | 0,49 |
Volume of water in the boiler, m³ | 0,22 | 0,27 | 0,53 | 0,6 | 0,68 | 0,94 | 1,2 | 1,3 | 2,1 | 2,3 | 2,6 | 3 |
Boiler heating surface, m² | 5,1 | 6,9 | 9,6 | 12,4 | 12,4 | 15 ,9 | 19,8 | 27,3 | 29,8 | 34,7 | 64,6 | 74,4 |
Adapting (connecting) pipes | conditional diameter, mm (inches) flange, Ø mm | 65 (2½") 160 | 65 (2½") 160 | 65(2½") 160 | 65 (2½") 160 | 65 (2½") 160 | 80 (3") 185 | 80 (3") 185 | 80 (3") 185 | 80 (3") 185 | 80 (3") 185 | 80 (3") 185 | 80 (3") 185 |
Overall dimensions not more | H - height, mm B - width, mm L * 5 - length, mm | 040 1100 1580 | 2040 1100 1750 | 2360 1250 1950 | 2360 1250 2150 | 2360 1250 2320 | 2780 1500 2400 | 2860 1500 2600 | 2860 1500 2840 | 2950 1650 3030 | 2950 1650 3220 | 3150 1870 3150 | 3150 1870 3545 |
Weight, not more, kg | 988 | 1170 | 1750 | 2000 | 2100 | 2800 | 3100 | 3500 | 4200 | 4700 | 5865 | 6735 |